![](/rp/kFAqShRrnkQMbH6NYLBYoJ3lq9s.png)
Made of AL29-4C stainless steel to capture more of the heat you pay for. Durable, quiet design holds more heat in the furnace to better warm your home. Manage every function with digital accuracy. Includes safety features and a built-in troubleshooting system. Ensures the quietest possible operation.
furnace installation in an attic should be on a service platform large enough to allow for proper clearances on all sides and service access to the front of the furnace (See Outline Drawings).
A gas-fired furnace for installation in a residential garage must be installed as specified in “Location and Clearances” section (pages 3 & 6), of these instructions.
All American Standard Heating & Air Conditioning S-Series gas furnaces have a Lifetime Registered Limited Warranty on the heat exchanger and a 10 year Registered Limited Warranty on internal functional parts (residential use only).
- [PDF]
Specification
American Standard Heating & Air Conditioning 6200 Troup Highway Tyler, TX 75707 Technical Literature - Printed in U.S.A. NATURAL GAS MODELS — Central heat-ing furnace designs are certified by the American Gas Association for both natural and L.P. gas. Limit setting and rating data were established and approved under stan-
American Standard furnaces, such as our Platinum 80, Gold 80V and Gold 80 models, feature multiple stages of heat that typically run at lower, more efficient stages.
Note: This unit can be used in AccuLinkTM mode or American Standard Link mode. located inside this unit or by searching for the Link Diagnostics App in your App Store®. Only qualified personnel should install and service the equipment.
American Standard Freedom 95 variable-speed, three-stage communicating furnace makes the most out of every energy dollar. And with advanced AccuLink™ communicating technology, this unit does something no other furnace has done before – it connects homeowners or your technicians with real-time operating information and remote programming by ...
The American Standard Freedom 90 high efficiency single-stage furnace has higher efficiency and is more reliable. It uses less electricity in heating and cooling operations, so it appeals to efficiency-minded customers in residential new construction and in retail replacement. And it accommodates upgrades to higher SEER outdoor units.
crucial aspects of installing an American Standard furnace, providing step-by-step insights, key considerations, and vital safety precautions. From understanding the pre-installation checklist to navigating the intricate wiring and venting procedures, we aim to empower you with the knowledge to successfully install your new furnace. This ...
VAC modes, the furnace can support single or multi stage heat pump, AC, or heating only applications. Combined with a communicating Comfort Control only, the furnace will support a single stage 24 VAC cooling outdoor unit only. It is recommended that Manual J of the Air Conditioning Contractors
NATURAL GAS MODELS — Central Heating furnace designs are certified by the American Gas Association for both natural and L.P. gas. Limit setting and rating data were established and approved under standard rating conditions using American …
• Dedicated Downflow furnace model ..... • Front service access with easily accessible burners, sensors, orifices, switches, and other components .....
Exclusively designed operational pro-gram provides total control of furnace limit sensors, blowers, gas valve, flame control and includes self diagnostics for ease of service. Also contains connec-tion points for E.A.C./humidifier.
2012年6月18日 · furnace. Align the bottom of the filter enclosure 1/4 inch above the bottom of the furnace. Mark the inside opening of the filter enclosure using the inside edge of the mounting flange as a guide. Move the enclosure and cut the opening. NOTE: Do NOT use the standard furnace indents for the opening. The opening for the filter enclosure must be ...
Central Heating furnace designs are certified by the American Gas Associa-tion for both natural and L.P. gas. Limit setting and rating data were estab-lished and approved under standard rating conditions using American Na-tional Standards Institute standards.
vides total control of furnace limit sensors, blowers, gas valve, flame control and in-cludes self diagnostics for ease of service. AIR DELIVERY — The multispeed, direct-drive blower motor, with sufficient airflow range for most heating and cooling re-quirements, will switch from heating to cooling speeds on demand from room thermostat.
Furnaces must have air for proper performance. There must be a free flow of fresh air sufficient for efficient combustion and safe ventilation of your furnace. The combustion air for your furnace must be fresh unconta-minated air.
Exclusively designed operational pro-gram provides total control of furnace limit sensors, blowers, gas valve, flame control and includes self diagnostics for ease of service. Also contains connec-tion points for E.A.C./humidifier.
Central Heating furnace designs are certified by the American and Canadian Gas Associations for both natural and L.P. gas. Limit setting and rating data were established and approved under standard rating conditions using American National Standards Institute standards.